In order to provide a harmonized framework for the study of light source data, we carry out our analyses based on the data model presented below: it defines the rules to be respected in the presentation of data, as well as the mandatory and optional infor-mation to be provided.
Data relating to the light points to be analyzed must be supplied in the form of a file complying with the following specifications:
File format: .csv with 20 fields, in which each line corresponds to a luminous point.
Character encoding: UTF-8
Field separators: comma
Decimal separator: dot
If required, you can download the sample file to be used, and complete it with your data.
Mandatory fields are indicated by the label “MANDATORY".
Only the geographic coordinates of each light point are required: latitude and longitude expressed in degrees (EPSG: 4326).
Alternatively, French users can enter x and y coordinates expressed in meters, provid-ed they also supply the INSEE code of the commune to which each light point belongs. The x and y coordinates must be expressed in one of the following official reference systems:
–Metropolitan France: RGF93LAMB93 (EPSG: 9794 or 2154)
–Guadeloupe and Martinique: RGAF09UTM20 (EPSG: 5490 or 4559)
–French Guiana: RGFG95UTM22 (EPSG: 2972)
–Reunion Island: RGR92UTM40S (EPSG: 2975)
–Mayotte: RGM04UTM38S (EPSG: 4471)
The label “RECOMMENDED" indicates a field taken into account to produce a map of the contribution of light points to overall light pollution (e.g. for the "Study of the impact of a set of light points" service on the Light Pollution Platform). If some of this infor-mation is missing, the map of light points' contribution to overall light pollution is pro-duced by replacing the missing data with default values.
Nom de la colonne
Description
Type
insee
INSEE code of the light point's commune (France only) - MANDATORY only if fields 'x' and 'y' are filled in.
Character string
commune
Name of the commune where the light point is located (France only)
Character string
siren
SIREN code of light point operator (France only)
Integral
reference
Light point reference (operator-specific identifier)
Character string
x
X coordinate of light point (France on-ly) - The 'insee' field must also be filled in.
Decimal
y
Y coordinate of light point (France on-ly) - The 'insee' field must also be filled in.
Decimal
latitude
Latitude of light point (EPSG: 4326) - MANDATORY unless fields 'insee', 'x' and 'y' are filled in.
Decimal
longitude
Longitude of light point (EPSG: 4326) - MANDATORY unless fields 'insee', 'x' and 'y' are filled in.
Decimal
puissance
Active power in nominal operation of the light point, expressed in watts - RECOMMENDED
Integral
flux
Nominal operating luminous flux from the light source, expressed in lumens.
Integral
type_luminaire
Type of light associated with the light point (this may be a simple designa-tion such as "style lantern" or "ball lamp", the brand of equipment, etc.).
Character string
type_source
Type of source associated with the light point - RECOMMENDED
Valeur à choisir parmi 13 possibilités : voir ci-dessous la section « Types de source »
ulr
ULR of the light point under operating conditions, expressed from 0 to 100, i.e. the fraction of flux emitted above the horizontal. - RECOMMENDED
Integral
temperature_couleur
Light source color temperature, ex-pressed in Kelvin - RECOMMENDED
Integral
hauteur
Light point height above the earth's surface, in meters.
Decimal
profil_nocturne
Light point operating profile. This field is used to specify the light point's switch-on time in the evening and switch-off time in the morning.
plages_variation
Ranges of variation (either complete extinction or dimming) of the light point during its operating period.
eclairage_adaptatif
Indication that the light point is con-trolled by an adaptive mechanism.
tag
Optional tag associated with light points. A tag can be used to associate specific information with light points for filtering purposes, for example.
commentaire
Optional comment associated with the light point.
Character string
The table below shows the permitted values for the 'type_source' field.
Value
Description
LED
LED-based device
SHP
High-pressure sodium lamp
SBP
Low-pressure sodium lamp
IM
Metal halide lamp
INC
Incandescent lamp
HAL
Halogen lamp
TF
Fluorescent tube
FC
Compact fluorescent lamp
VM
Mercury vapor lamp (also known as a "fluorescent balloon")
IND
Induction lamp
XEN
Xenon lamp
AU
Other lamp type not listed
XX
Lamp type not available. This value is equivalent to leaving the field blank.